Pump Innovation Reduces Motor Size
Where HPI process conditions incorporate high-head, low-flow slipstreams, such
as with fractionator reflux services, common practice is to oversize pumps to envelop
the slipstream requirements. It is often not practical to use a second small pump.
A recent innovation from Flowserve incorporates an auxiliary low-flow impeller
in an API Standard 610 overhung process pump. It allows the pump to separate the
inlet flow into a primary high-flow, low-head discharge and a secondary lower-flow,
higher-head discharge.
The pump is effectively two pumps-in-one, with each impeller selected for the
discrete process requirements of each flow stream. This Split Flow concept saves
energy by allowing use of smaller motors when pumps are sized for two (or more)
process conditions with one discharge flow stream at a higher head and lower flow
than the other.
Two prototype 4-in. x 6-in. x 10-in., 3,600-rpm pumps with 60-hp motors and
incorporating the Split Flow feature have been operating in a California refinery
since June 1996 (Fig. 1). The conventional pump selection would have required 125-hp motors.
The only modification to existing standard pumps is to the back cover and shaft
(Fig. 2). This lends itself to retrofits and debottlenecking modifications. Seal
selection is not restricted and seal life is not compromised as shaft deflection at
the seals is within API standards, i.e., deflection resulting from the slightly
longer shaft cantilever is offset by lower dynamic deflection forces due to use of a
smaller-diameter, lower-head primary impeller.
|